Contact us at (866) 894-1113


Largest Nationwide Service & Support Network in the U.S.

Fuji FDR ES Detectors

Fuji FDR ES Detectors
FDR ES - Essential DR: Affordability without compromise. Fast, easy integration with any x-ray room to transition to the speed, image quality and dose benefits of Fujifilm Digital Radiography
Description

Details

FDR ES DR Detectors

FDR ES detectors are the next generation of DR retrofit solutions designed with the essential conveniences of Fujifilm image acquisition and design. Light, portable, affordable detectors can optimize your x-ray room for table and free positioning and table top exams with top of the line image quality. There's also no need to re-work your existing equipment because FDR ES fits existing standard Buckys and holders.

High image quality from low dose
As a world-leading imaging and information company, Fujifilm is dedicated both to improving image quality and advancing dose lowering technologies and safe healthcare standards for patients. FDR ES is a perfect example. It features engineering innovations which achieve dose efficiency improvements by as much as 30% compared to Fujifilm CR and as much as 20% over comparable DR detector designs, all while delivering exceptional images.

FDR ES Sizes
FDR ES 24X30 cm CsI (C24)
FDR ES 14x17" CsI (C35)
FDR ES 17x17" CsI (C43)
FDR ES 14x17" GOS (G35)
FDR ES 17x17" GOS (G43)
Contact us for specific panel information

Additional Information

Additional Information

Specifications

Physical Specifications
Scintillator Options Include - GOS (Gadolinium Oxysulfide) or CsI (Cesium Iodide) depending on size
Dimensions - depend on specific panel
Weight (with battery) - depends on specific panel, ranges from 3.5 lbs to 8 lbs
Load Resistance - 264 lbs point load, 600 lbs distributed (protective cover required for standing exam)
Water Resistance - IPX3

Image Acquisition
Max. Exposure Time - 10 seconds
Bid Depth, Pixel Pitch - 16 bit, 150um
Preview - 2 seconds
Cycle - depends on specific panel, ranges from 7.5 sec. to 9 sec.
Gird Frequencies - 40 lines/cm recommended; 40-44 lines/cm, 80 or more lines/cm usable
Virtual Grid™ (option) simulates scatter clean-up for images acquired without a grid.

Connectivity
Detector to FDX Console - Tethered or Wireless - IEEE 802.11n in 2.4 & 5 GHz bands. Wireless in-room 33' (approx.) range, closed loop, image data only (no patient info.). WPA2-PSK encrytption with AES & MAC (unique IP) protocols secure connection, confirmation and completion of data, handshake pairing to registered FPDs only. FDX Console to Network - LAN wired Ethernet: 10/100/100 Base-T, DHCP or Static

More Information

Battery
Battery - Lithium ION, user swappable
Charge Time (approx.) - Battery Charger: 3 hours / Power Box SE Cable: 4.5 hours / MP SE Cable: 4 hours
Quick charge (approx.) - After low battery alarm: 3 min. charge allows up to 30 images ( battery charger or power supply)

Environmental and Power
Temp, Humidity, Atmospheric Pressure - Operating: 59-86° F, 15-80%RH(non-condensing), 700-1,060 hpa
Non-Operating: 41-95° F, 10-80%RH (nc), 700-1,060 hpa
Storage (packed): 14-122° F, 10-90%RH (nc), 700-1,060 hpa

Power Conditions - single phase 50/60 Hz Std 110VAC
Power Box/MP Box: 100-240VAC (+/-10%), 200VA or less,
FDX Console: 115/230VAC (auto), 460VA or less
Battery Charger: 100-240VAC (+/-10%), 100VA or less

Heat output - Detector: 316Kj/h

Power Consumption - FDX Console: 110W(operating), 90W (standby)
MP Box and 2 Detectors: 88W
Power Box and 1 Detector: 22W
Battery Charger: 50W (operating), 5W (standby)

REQUEST QUOTE

Personal Info

  • all numbers no dashes

Company Information

Product Information

* Required Fields